FAQ

Yes. FirePASS® oxygen reduction systems are engineered according to the requirements of the individual application and protected space. Systems are available for smaller rooms as well as very large facilities, and FirePASS states that its systems can protect single or multiple rooms and compartments, with configurations tailored to the application, location, protected volume and customer requirements.

This scalability allows oxygen reduction fire prevention to be applied to environments ranging from server rooms and archives to data centers, high-bay warehouses and large industrial facilities. Oxygen monitoring, system capacity and control parameters can be designed around the specific fire protection requirements of each application.

Read more

Retrofitting may be possible, depending on factors such as room airtightness, ventilation, HVAC systems, occupancy and existing fire protection infrastructure. A technical assessment is required to determine whether oxygen reduction is suitable for a particular facility.

Read more

Yes. FirePASS® oxygen reduction systems can be engineered for automated storage and retrieval systems (ASRS), including high-density and high-bay storage environments. By helping prevent ignition, FirePASS® protects valuable inventory, automated handling equipment and critical warehouse infrastructure while supporting operational continuity.

Read more

Yes. FirePASS® provides its preventive function by controlling the oxygen concentration in the protected environment, without relying on water discharge or chemical extinguishing-agent release. This helps avoid the potential secondary damage associated with conventional suppression methods.

Read more

Yes. FirePASS® oxygen reduction systems can be designed for environments containing historical documents, rare manuscripts, books, artworks and other valuable collections. By helping prevent ignition without relying on water discharge or chemical extinguishing agents, FirePASS® offers an approach to protecting sensitive materials from fire and potential secondary damage associated with conventional suppression methods.

Read more

By helping prevent ignition, FirePASS® oxygen reduction technology can reduce the risk of fire-related damage to inventory, automation equipment and warehouse infrastructure. This preventive approach supports business continuity and can help minimize operational disruption associated with fire incidents and subsequent recovery activities.

Read more

Yes. Oxygen reduction fire prevention can be particularly suitable for environments containing sensitive equipment and high-value assets because prevention-mode protection does not depend on discharging water or chemical extinguishing agents into the protected space.

This makes the technology relevant to applications such as data centers, server rooms, electrical switch rooms, archives, automated warehouses and other mission-critical facilities, where conventional fire suppression could result in additional equipment damage, contamination or operational downtime. The suitability and required oxygen level depend on the specific facility, materials and fire protection design.

Read more

FirePASS® oxygen reduction technology may be suitable for both new facilities and existing museum or archive buildings. Feasibility depends on factors such as room airtightness, ventilation, building characteristics, occupancy and collection requirements. A technical assessment is necessary to determine the appropriate system design, particularly for historic buildings with specific preservation constraints.

Read more

Yes. FirePASS® offers scalable oxygen reduction solutions for large storage facilities and high-bay warehouses. For example, FirePASS® completed a fire prevention project for a 230,000 m³ automated warehouse in Riga, Latvia, demonstrating the application of oxygen reduction technology in large-scale logistics environments.

Read more

Yes. FirePASS® technology can be engineered for multiroom data center environments. For example, FirePASS® completed a project in Saku, Estonia, involving five data halls and 32 oxygen monitoring units, demonstrating the application of oxygen reduction fire prevention across multiple protected spaces.

Read more

No. FirePASS® provides its preventive function by controlling oxygen concentration rather than discharging water or chemical extinguishing agents. This makes oxygen reduction particularly relevant for archives, museum storage facilities and cultural heritage environments where sensitive materials may be vulnerable to water damage or extinguishing-agent residue.

Read more

No. FirePASS® does not create an oxygen-free environment. The system reduces the oxygen concentration to a carefully engineered level determined by the specific application, materials, operating conditions and fire protection requirements.

Read more

By helping prevent ignition, oxygen reduction technology can reduce the risk of fire-related equipment damage and operational interruptions. This supports business continuity and uptime objectives, although overall availability also depends on the facility's wider infrastructure and operational resilience.

Read more

No. One of the main differences between oxygen reduction and conventional fire suppression is that the protective atmosphere is maintained continuously. FirePASS® therefore provides active fire prevention before an ignition event occurs rather than waiting for a fire alarm before providing protection.

Read more

No. FirePASS® oxygen reduction fire prevention uses oxygen-reduced air produced from ambient air rather than water or chemical extinguishing agents. Ambient air is processed to create oxygen-reduced air, which is continuously supplied to the protected environment while oxygen sensors and system controls maintain the specified conditions.

Because prevention-mode protection does not rely on sprinkler discharge or chemical extinguishing agents, it can help avoid water damage, chemical residue and the cleanup associated with those suppression methods.

Read more

Yes. FirePASS® successfully completed and commissioned an Oxygen Reduction Fire Prevention System at a state archive in The Hague, Netherlands, in February 2026. The project demonstrates the application of oxygen reduction technology in an archival environment where protecting historical documents, valuable records and irreplaceable collections is a key priority.

Read more

FirePASS® uses oxygen monitoring and system controls to continuously measure and regulate conditions within the protected environment. Oxygen-reduced air is supplied as required to maintain the specified operating range.

Read more

An oxygen reduction system continuously produces oxygen-reduced air and supplies it to a controlled protected environment. Oxygen sensors monitor the atmosphere while the system regulates conditions to maintain the engineered oxygen concentration. This reduces the oxygen available for combustion and makes many common materials significantly more difficult to ignite.

Read more

FirePASS® continuously maintains a precisely controlled, oxygen-reduced atmosphere within protected spaces. By reducing oxygen availability to an engineered setpoint, the system creates conditions designed to prevent ignition of relevant combustible materials. Continuous oxygen monitoring and automatic regulation help maintain the required protective atmosphere, reducing the risk of fire damage to valuable collections.

Read more

FirePASS® continuously reduces and controls the oxygen concentration within protected data halls or server rooms. By maintaining an engineered oxygen setpoint, the system creates atmospheric conditions designed to prevent ignition of relevant combustible materials under specified conditions. Continuous oxygen monitoring and automatic regulation help maintain the required protective atmosphere.

Read more

FirePASS® continuously reduces and regulates the oxygen concentration within the protected warehouse to an engineered setpoint. This creates atmospheric conditions designed to prevent ignition of relevant combustible materials under specified operating conditions. Continuous oxygen monitoring and automatic regulation help maintain the required protective atmosphere around the clock.

Read more

Oxygen reduction prevents fire by controlling the amount of oxygen available for combustion. Fire requires sufficient heat, fuel and oxygen to ignite and continue burning. By reducing the oxygen concentration within a controlled environment, the conditions for ignition and combustion are significantly restricted.

FirePASS® continuously introduces oxygen-reduced air and monitors the oxygen concentration within the protected space. Rather than waiting for smoke or flames to trigger a suppression system, the protective atmosphere is maintained continuously.

This means oxygen reduction fire prevention works before a fire event develops, helping reduce the risk of ignition and subsequent fire damage.

Read more

The main difference between oxygen reduction fire prevention and fire suppression is when the protection takes place. Traditional fire suppression systems detect and respond to a fire after ignition, using methods such as water, foam, gas or other extinguishing agents to control or extinguish it.

Oxygen reduction fire prevention takes a proactive approach. The protected environment is continuously maintained at a controlled oxygen concentration designed to inhibit ignition. Rather than waiting for a fire event, FirePASS® addresses one of the essential conditions required for combustion and provides continuous protection against the development of fire.

Read more

Oxygen reduction systems require careful consideration of personnel safety. The appropriate oxygen concentration, access procedures and occupational safety measures depend on the specific installation and applicable regulations. FirePASS® systems are engineered with these requirements in mind, including continuous oxygen monitoring and control.

Read more

Personnel safety is a fundamental consideration in oxygen reduction system design. The suitability of a reduced-oxygen environment depends on the selected oxygen concentration, occupancy conditions, exposure duration and applicable occupational safety requirements. FirePASS® systems incorporate continuous oxygen monitoring and atmospheric control, while appropriate access procedures and safety measures must be established for each installation.

Read more

Personnel safety is an essential consideration when designing oxygen reduction fire prevention systems. The appropriate oxygen concentration, occupancy conditions, access procedures and safety measures must be determined according to the facility's requirements and applicable occupational safety regulations. FirePASS® systems are engineered with continuous oxygen monitoring and atmospheric control to support safe operation under defined conditions.

Read more

Yes. Oxygen reduction technology can be particularly suitable for cold storage and temperature-controlled warehouses, where water-based fire suppression may introduce additional challenges related to freezing, inventory damage and operational disruption. FirePASS® has successfully completed an FP-5000 Twin oxygen reduction project for a 45,000 m³ ASRS cold storage warehouse in Estonia.

Read more

Traditional fire suppression systems are primarily designed to react after ignition. Once a fire is detected, water, foam, inert gas or another extinguishing agent is used to control or extinguish the fire.

Oxygen reduction fire prevention is proactive. The atmosphere within the protected space is continuously maintained at a controlled oxygen concentration designed to reduce the likelihood of ignition before a fire develops.

FirePASS® technology can also be engineered for fire suppression. In suppression mode, the oxygen concentration is reduced further toward the combustion-inhibition level required to extinguish a fire. Fire prevention and fire suppression therefore have different objectives, even though both can use oxygen reduction technology.

Read more

An oxygen reduction system is a fire prevention system that continuously maintains a controlled, low-oxygen atmosphere within a protected space. Instead of reacting after a fire has started, the system is designed to reduce the conditions required for ignition.

FirePASS® produces oxygen-reduced air from normal ambient air and continuously supplies it to the protected environment. Oxygen sensors monitor the atmosphere, while the control system maintains the engineered oxygen concentration.

This creates a continuously protected environment in which many common combustible materials are far less likely to ignite, making oxygen reduction a proactive alternative or complement to conventional fire suppression.

Read more

Oxygen reduction fire prevention is a proactive fire protection method that continuously maintains a controlled, low-oxygen atmosphere within a protected space. By reducing the oxygen concentration from normal atmospheric levels to an engineered setpoint, conditions are created in which many common combustible materials are far less likely to ignite.

Unlike traditional fire suppression, which responds after a fire has started, oxygen reduction technology is designed to reduce the risk of ignition before a fire can develop. FirePASS® achieves this by continuously supplying oxygen-reduced air while monitoring and controlling oxygen levels within the protected environment.

Read more

The most suitable fire protection system depends on the warehouse design, storage configuration, combustible materials and operational requirements. FirePASS® oxygen reduction technology offers a preventive solution for automated storage and retrieval systems (ASRS), high-bay warehouses and other critical logistics facilities. By maintaining a controlled, low-oxygen atmosphere, FirePASS® helps prevent ignition before a fire can develop.

Read more

The most suitable fire protection system depends on the facility's design, equipment and operational requirements. FirePASS® oxygen reduction technology offers a preventive approach by maintaining a controlled low-oxygen atmosphere designed to prevent ignition, rather than relying solely on fire suppression after a fire has started.

Read more

The most suitable fire protection system depends on the type of collection, building design and preservation requirements. FirePASS® oxygen reduction technology offers a preventive approach by maintaining a controlled, low-oxygen atmosphere designed to prevent ignition. Unlike conventional fire suppression systems, FirePASS® focuses on preventing fires before they can damage irreplaceable artworks, historical documents and archival collections.

Read more

Gas fire suppression systems generally release an extinguishing agent after fire detection. Oxygen reduction systems take a different approach by continuously maintaining a reduced-oxygen atmosphere designed to prevent ignition. The key difference is continuous prevention versus suppression after a fire has started.

Read more

Sprinkler systems are designed to control or suppress a fire after activation, typically using water discharge. FirePASS® takes a preventive approach by continuously maintaining a reduced-oxygen atmosphere designed to inhibit ignition. Unlike sprinkler-based protection, the FirePASS® prevention process does not require water discharge, helping avoid potential water damage to stored goods and automated equipment.

Read more

Traditional fire suppression systems are generally designed to control or extinguish a fire after ignition, often using water or extinguishing agents. FirePASS® takes a preventive approach by continuously maintaining an oxygen-reduced atmosphere designed to inhibit ignition. This helps protect irreplaceable collections before fire, smoke or extinguishing operations can cause damage.

Read more

The oxygen concentration required for oxygen reduction fire prevention depends on the combustible materials present, the characteristics of the protected environment and the engineered fire protection design.

Normal ambient air contains approximately 20.9% oxygen. FirePASS® states that its oxygen-reduced fire prevention environments typically operate at around 15% oxygen, although the required setpoint must be determined for the specific application. Different materials have different ignition thresholds, so there is no single oxygen concentration that should be applied to every facility.

FirePASS® systems therefore use continuous oxygen monitoring and control to maintain the specified oxygen concentration for each protected environment.

Read more

Oxygen reduction fire prevention can be used in enclosed and controlled environments where preventing fire and protecting critical assets are essential. Typical applications include data centers, automated and high-bay warehouses, archives, museums, switch rooms and substations, aerospace facilities, mining environments and other critical infrastructure.

FirePASS® systems can be engineered around the size, use and specific fire protection requirements of the protected area. This makes oxygen reduction particularly relevant for facilities where fire, smoke, water or chemical extinguishing agents could result in significant damage or operational disruption.

Read more